Conductor : bare copper conductor of class 1 (solid) acc, to IEC 60228 / HD 383 / DIN VDE 0295
fixed installed : -30 °C up to+70 °C
APPLICATION : public areas
Insulation : PVC compound TI1 acc. to IEC 60227-3 / HD 21.3 S3 / DIN VDE 00281 part 3
Test voltage : 2500 V
Minimal inner bending radius : 4D
Place of Origin : Guangzhou, China
Brand Name : SUNWIN
Certification : ISO9001, ISO14001, OHSAS18001
MOQ : Negotiable
Price : Negotiable
Packaging Details : 100 m / tied, or customized
Delivery Time : 10 day
Payment Terms : 30% deposit, the balance is settled on the delivery date
Supply Ability : 100,000 m / month
318 BLSZH Pure Copper Three Wire Electrical Cable , Pvc Insulation Wire
Insulated conductor is used for laying in electric-installation tubes, under and on plaster installation in dry rooms and in closed installation conduits. Direct laying in cable guides is not permitted. Also applied for internal wiring of distribution and switching boxes equipment, same as for protective laying for lighting of nominal voltage up to 1000 V alternating current, or up to 750 V direct current against earth.
HRN HD 21.3 S3
IEC 60227-3
DIN VDE 0281 part 3
Temperature range: | |
during installation: | +5 °C up to+70 °C |
fixed installed: | -30 °C up to+70 °C |
at short circuit of max. 5 s.: | up tp 160 °C |
ambient temperature at storage: | up pt 40 °C |
Nominal voltage: | Uο/U = 450/750 V |
Test voltage: | 2500 V |
Minimal inner bending radius: | 4D |
Behaviour in fire: | IEC 60332-1 |
Conductor: | bare copper conductor of class 1 (solid) acc, to IEC 60228 / HD 383 / DIN VDE 0295 | |
Insulation: | PVC compound TI1 acc. to IEC 60227-3 / HD 21.3 S3 / DIN VDE 00281 part 3 | |
Conductor colour identification: | acc. to IEC 60446 i.e. EN 60446 (corresponding to DIN VDE 0293) | |
possible insulation colours: | ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | |
- yellow-green color is used only for protecting conductor, and green and yellow ones are permitted only if allowed by security regulations, i.e. if they can not get mixed up with the yellow-green conductor | ||
- blue color is used for neutral conductor, black and brown are applied for alternating current phase conductors |
Dimensions – conductor cross-section
Construction of individual conductor | External diameter | Insulation thickness | Conductor resistance at 20 °C | Specific. el. resistance of insulation at 70°C | Cu weight | Cable weight | Packing* | |
nominal | min-max. | nominal | max. | min. | approx | |||
mm² | n x mm | mm | mm | Ω/km | MΩkm | kg/km | kg/km | |
1,5 | 1 x 1,38 | 2,6 - 3,2 | 0,7 | 12,10 | 0,011 | 14,4 | 20 | c.100 |
2,5 | 1 x 1,78 | 3,2 - 3,9 | 0,8 | 7,41 | 0,010 | 24,0 | 31 | c.100 |
4 | 1 x 2,26 | 3,6 - 4,4 | 0,8 | 4,61 | 0,0087 | 38,4 | 46 | c.100 |
6 | 1 x 2,70 | 4,1 - 5,0 | 0,8 | 3,08 | 0,0070 | 57,6 | 65 | c.100 |
10 | 1 x 3,5 | 5,3 - 6,4 | 1,0 | 1,83 | 0,0072 | 96,0 | 110 | c.100 |
*) *) Packing: c.100 = coil 100 m
![]() |